Skip to content
Free courier delivery is available for purchases above RM500 within West Malaysia (Shipping and installation conditions apply and are available on each product page). Call us to confirm product availability before visiting our showroom.
Free courier delivery is available for purchases above RM500 within West Malaysia (Shipping and installation conditions apply and are available on each product page). Call us to confirm product availability before visiting our showroom.

Syringe Pump Top-5530

SKU HMAH012
Original price RM 5,500.00 - Original price RM 5,500.00
Original price
RM 5,500.00
RM 5,500.00 - RM 5,500.00
Current price RM 5,500.00

 

A Syringe Pump Top-5530 with outstanding capabilities and ease of use in the clinical setting, whether on the general ward or when administering an anesthetic. 


Product Specification

  • Syringe pump model 5530
  • User friendly
  • Very high precision
  • Self-test system (automatic malfunction detection)
  • Automatic syringe detection
  • Compatible with all kind of syringes (no need to manual adjustment)
  • Can be used with 10, 20, 30 and 50 ml syringes
  • Long lifetime and durability
  • KVO feature
  • Ability to set occlusion alarms scope
  • Ability to adjust injection speed
  • Ability to turn off automatically
  • 360′ performance LED display
  • The “drug library” function makes medical information and previous registered settings available.
  • Made in Japan

 

Technical Specification:

1) Power SUPPLY:

  • AC power source : AC 100 -127 ±10% 50/60Hz (for 100V Area) , Ac 200-240 V ±10% 50/60Hz (for 100V Area)
  • DC power supply : DC 12V ±5% (type: ST55-4)
  • Internal battery : DC3.6V 1500mAh NI-MH (type : BP-55); battery life is approximately 12 hours (at flow rate of 5 mL/h using new battery in fully recharged state )
  • Built-in battery : Rechargeable, DC 12V 700mAh NI-CD Model : BP-53
  • Alkaline battery : uses four LR6 type , AA size alkaline batteries DC6V battery life is approximately24 hours (at flow rate)

2) Power consumption external :

  • AC power source : 0.3A ( approx.)
  • External DC power source : 0.5A ( exact )

3) Applicable syringes
- 10mL, 20mL, 30mL and 50mL syrings from

  • TOP, TERUMO, B-D or B. BRAUN
  • B-D, TERUMO, MONOJECT or B.BRAUN can be used ( in the auto selecation [*] mode, only the 50 mL syringe can be used ).

4) Flow rang

  • 0.1-400.0 mL/h (10mL syringe)
  • 0.1-700.0 mL/h (20mL syringe)
  • 0.1-900.0 mL/h (30mL syringe)
  • 0.1-1500.0mL/h (50mL syringe )
  • ( setting Adjustable in 0.1mL increments.)

5) Total infusion volume range

  • 0.1-999.9 mL

6) Infusion accuracy
- Brand – specififed mode

  • Mechanical accuracy : ±1%
  • Accuracy including the syring : ±3%
  • Auto selection [*] mode (only 50ml syringe can be used.)
  • Mechanical accuracy : ±1%
  • Accuracy including the syringe :±3%
  • Accuracy obtained when infusion is performed for over one hour
    at an infusion rate of 1.0mL/h or more.

7) Bolus rate

  • Approx 400.0mL/h (10mL syringe)
  • Approx 700.0mL/h (20mL syringe)
  • Approx 900.0mL/h (30mL syringe)
  • Approx 1500.0mL/h (50mL syringe)


8) Step selection

  • Extra high : 119.7±40.0kpa/ 900±300mmHg/ 1.22±0.41 kgf/ cm2
  • High : 93.1±33.3kpa/ 700±250mmHg/ 0.95±0.34 kgf/ cm2
  • Middle : 66.5±26.7kpa/ 500±200mmHg/ 0.68±0.27Kgf/cm2
  • Low : 39.9±20.0Kpa/ 300±150mmHg/ 0.41±0.20Kgf/ cm2

9)Alarm

  • Low volume (inactive in the auto selection [*] mode), occlusion, low battery, syringe barel/ syring plunger clamp disengaged, power source switch, remainder, CPU error.

10) Special functions

  • Operation Reminder: If the system is left in the suspend state for approximately three minutes, a buzzer will sound.
  • Auto power off: If the system is left in the "Operation Reminder" state for another three minutes while ti is powerd by an internal battery, it will be automatically shut off .
  • Alarm Repeat: If two minutes have elapsed without resetting the alarm after it is silenced the alarm sounds again.
  • Data memorize : Infusion rate set value/Total infusion volume storage setting is allowed.
  • Buzzer setting : Presence/Absence of wait tone and operation tone can be speficied.
  • Power source switch alarm : Notifies by the alarm sound that power is no longer supplied from the AC or DC power source and the system has entered the battery operation mode.

11) Operation conditions :

  • Ambient temperture : 10 to 40 °C
  • Relative humidity : 30 to 85% ( no condensation )
  • Atmospheric pressure : 70 to106kpa

12) Transportation and storage conditions :

  • Ambient temperture : -10 to 45 °C
  • Relative humidity : 10 to 90% ( no condensation )
  • Atmospheric pressure : 50 to 106kpa

13) Classification :

  • Class I and Internally powerd equipment, Type CF♥, IPX1 (drip proof)

14) Fuse : T1A

Features and Benefits
Product Specifications

Product Specifications

Dimensions : Approx 320(W)x116(H) X 139(D)mm /
Weigt : Approx 2.2kg

Certification
Warranty

1 year warranty on manufacturing defects.

Shipping & Installation

iElder Signature Elder Care Furniture

Featured Brands

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare